APPENDIX A: QUESTIONS AND ANSWERS
Q1: How to configure transparent serial port application (TCP protocol) with
two DTU devices?
Network structure as below figure:
DTU 1# Setting:
Works as AP mode; --See “Mode Selection Page”
LAN IP address: 10.10.100.254; --See “AP Interface Setting Page”
Network Protocal:TCP/Server, Port ID: 8899; -- See “Application Setting Page”
(DTU default setting);
DTU 2# Setting:
Works as STA mode; --See “Mode Selection Page”
WAN connection type: DHCP or Static IP (For this example:10.10.100.100)
--See “STA Interface Setting Page”
Network Protocal:TCP/Client, Port ID: 8899; Application IP address: Module 1#‟s LAN
IP address (10.10.100.254); -- See “Application Setting Page”
Notes: When DTU 2# works as STA mode, DTU's WiFi interface works as WAN port.
DTU‟s WAN IP address and LAN IP address shall be setting different segment. So,
DTU 2#‟s LAN IP address must change to other segment; (For this sample, we change
to 10.10.99.254); --See “AP Interface Setting Page”
DTU
AP,
LAN IP:10.10.100.254
TCP, Server
8899
DTU
STA,
LAN IP:10.10.99.254
WAN IP: 10.10.100.100
TCP, Client
10.10.100.254: 8899
1# 2#
WIFI
MCU
MCU
UART
UART
Figure 39. Configure Transparent Serial Port Connection (TCP)
Q2: Where to SetDTU LAN IP and WAN IP through Web Page?
DTU Wireless LAN IP address setting see “AP Interface Setting Page” as below Figure,
Figure 40. DTU LAN IP Setting