User's Manual
DTU-H100 Wi-Fi/Ethernet to RS485/RS232 Server User Manual
http://www.iotworkshop.com - 60 -
Set Operation
AT+ EPHY=<CR>
+ok<CR>< LF ><CR>< LF >
Ethenet port function is disabled bydefault. Input this command to enable Ethenet. This command
is not saved, this means after the device reset, Ethenet is disabled by default. Input “AT+FEPHY=on"
to enable Ethenet forever..
5.2.2.42. AT+STTC
Function: Enable/Disable STA port scan function;
Format:
Query Operation
AT+ STTC<CR>
+ok=<sta><CR>< LF ><CR>< LF >
Set Operation
AT+ STTC=<on/off><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
sta: when query, this value feedback
On: Enable STA port scan function;
Off: Disable STA port scan function;
5.2.2.43. AT+DOMAIN
Function: Set/Query domain ofdevice webpage;
Format:
Query Operation
AT+ DOMAIN<CR>
+ok=<domain><CR>< LF ><CR>< LF >
Set Operation
AT+ DOMAIN=<domain><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
domain: domain to acess to device webpage.
5.2.2.44. AT+FRLDEN
Function: Enable/Disable nReload pin function;
Format:
Query Operation
AT+ FRLDEN<CR>
+ok=< on/off ><CR>< LF ><CR>< LF >
Set Operation
AT+ FRLDEN=<on/off><CR>
+ok<CR>< LF ><CR>< LF >
Parameters:
on/off: Enable or Disable nReload pin function.