User's Manual

DTU-H100 Wi-Fi/Ethernet to RS485/RS232 Server User Manual
http://www.iotworkshop.com
40
PLC Device
RS
232
/
RS
485
AP IP: 10.10.100.254
STA IP: 10.10.101.100
AP IP: 10.10.101.254
AP
STA
PLC Device
RS
232
/
RS
485
Figure 34. Transparent Serial Port Application
For up side device, configured as AP mode and use default SSID and IP address changed to
10.10.101.254, network protocol configured as TCP/Server mode, and protocol port ID: 8899.
For down side device, configured as STA mode and setting the same SSID with up side device,
enable DHCP network and network protocol configured as TCP/Client mode, protocol port ID:
8899. Target IP address part setting the same IP address with up side device (“10.10.101.254"
for this example).
When down side device boot up, it will find wireless AP and open TCP/Client network protocol to
connect with up side device‟s TCP/Server. All these operation will be automatic and after finished,
the two user devices connected to device through serial port can communicate each other and
think the connection between them is fully transparent.
4.3.4. Wireless Data Acquisition Card Application
For this wireless data acquisition card application, one PC works as data server and every data
acquisition card connects with a device to support wireless connection function.