User's Manual

HF-BL100-CU Low Energy BluetoohBLE 4.0Module User Manual
Shanghai High Flying Electronics Technology Co., Ltd www.hi-flying.com - 29
-
when connect to IOS APP Apple has their own regulation, for parameter must comply
1. IntervalMax*Slave Latency+1)《=2 seconds
2. IntervalMin>=20ms
3. IntervalMin +20ms<=IntervalMax
4. Slave Latency<=4
5. connSupervision Timeout<=6 seconds
6. IntervalMax*(Slave Latency+1)*3<connSupervisionTimeout
Feedback
"AT:WRONG\r\n" means invalid parameter, modify failed
"AT:OK\r\n" means success, run with new connect interval
"AT:ERP\r\n" means invalid command, modify failed
4.3.5. Query Connect Parameter
FunctionQuery module connect parameter
Effective timeimmediately
Command
"AT:CIT?"+<CR><LF>
Feedback
"AT+CIT-"+IntervalMin+IntervalMax+Slave Latency+connSupervision Timeout+<CR><LF>
IntervalMin4 character means HighByte |...| LowByte;‟0‟~‟9‟ means 0~9”0200”->
decimal 200*1.25ms
IntervalMax4 character meansHighByte |...| LowByte;‟0‟~‟9‟ means 0~9”1000”->
decimal1000*1.25ms
Slave Latency:1 character‟0‟~‟9‟ means 0~9
connSupervision Timeout4 character means HighByte|...|LowByte‟0‟~‟9‟ means
0~9”2000”-> decimal 2000*10ms
when connect to IOS APP Apple has their own regulation, four parameter must comply:
7. IntervalMax*Slave Latency+1)《=2 seconds
8. IntervalMin>=20ms