User's Manual

HF-A21-SMT Embedded WiFi Module User Manual
Shanghai High-Flying Electronics Technology Co., Ltd
www.hi-flying.com
35
3.3.2. Remote Management Application
Figure 35. Remote Management Application
For this remote management application, HF-A21-SMT works as STA mode and connects to
Internet through wireless AP. Module configured as TCP Client and communicates with remote
TCP server at Internet. Module‟s serial port connects to user device.
So, user devices data or sampling information can send to remote TCP server for storage or
processing. Also remote TCP server can send command to control and manage the user device
through the wireless network.
3.3.3. Transparent Serial Port Application
For this transparent serial port application, two HF-A21-SMT modules connect as below figures to
build up a transparent serial port connection.
Figure 36. Transparent Serial Port Application
For left side HF-A21-SMT module, configured as AP mode and use default SSID and IP address,
network protocol configured as TCP/Server mode, and protocol port ID: 8899.
For right side HF-A21-SMT module, configured as STA mode and setting the same SSID HF-
A11x_AP” for this examplewith left side HF-A21-SMT module, enable DHCP network and
network protocol configured as TCP/Client mode, protocol port ID: 8899. Target IP address part
setting the same IP address with left side HF-A21-SMT module (“10.10.100.254” for this
example).