- High End System SHOWGUN User's Manual
CHAPTER 5
Maintenance and Troubleshooting
SHOWGUN
®
 User Manual  39
The SHOWGUN fixture uses a proprietary 2000 watt short arc metal halide lamp with a fast fit 
base.
DANGER-INTENSE HEAT: 
Equipment surfaces may reach temperatures up to 150° C (302° F). 
Allow the fixture to cool before handling.
To change the lamp:
2. Rotate the lamp base to 
align with the slots in the 
housing and pull out of the 
fixture.
Replace with a PHILIPS 
MSR Gold SA/SE only (HES 
part # 55030084)
3. Use the three Phillips head 
screws for lamp 
optimization.
1. Loosen the two captive 
screws open the lamp panel 
to access the base of the 
lamp.