Owner manual

Part No:- 021-00155 RevD7 PowerLine System Controller User Guide Page | 32
PowerLine User Guide
Help:
The ‘Help’ dropdown menu offers two
choices. The first opens a window that gives
the user information on the controller
Application and BIOS versions as well as
contact information for High Country Tek,
Inc.
The second option ‘View Help’ will open a
PDF file of this manual to allow the user
immediate access to information regarding
the controller, application, set-up and
troubleshooting.
Software Controls:
Exit the program (GUI)
Click the ‘Exit’ button on the man screen lower right hand corner.
NOTE:
Always use this method of terminating the PowerLine PC program. This cleanly exits the program and
also releases any communications port(s) in use for other applications.
Log Data
A data-logging feature is available to log the RPM, Coil Current and
RPM set point. This feature is useful for system troubleshooting and
remote debugging. The Log Data button is used to start the data
log process. The user is prompted for a file name and location after
the data has been collected. The data log contains 250 samples.
The timer period of the data log is less than a half of a minute on a
fast computer, to several minutes on a slow computer. The log file
is text and may be read into a spreadsheet and graphed.