Owner manual

Part No:- 021-00155 RevD7 PowerLine System Controller User Guide Page | 14
PowerLine User Guide
Electrical Specification Overview:
1 - Board Style: High Country Tek unique size and mounting.
2 - Connector Type: 12 way heavy duty screw terminal.
3 - Input Supply Voltage: 9 – 30VDC ( absolute maximums )
4 - Input supply current: ~400mA quiescent + valve currents
5 - Input supply protection:
User supplied in-line fuse ( AGC5 )
6 - User Reference Voltage: +5VDC ( +/- 10% ) – short circuit protected.
7 - User Reference Voltage current: ~5mA ( Absolute maximum ) current limited.
8 - Command Input types: DC Voltage and pulse
9 - DCV Command input value range: 0 – 5VDC or 0 – 10VDC
10 - DC Current Command Input Range 4 – 20mA ( 100 Ohm resistor load )
11 - Pulse Command input value range: 0 – 30 KHz
12 - Pulse command voltage range: ±0 – ±30V absolute max.
13 - Enable input value range: 0 – 5V or +module supply
14 - Enable input impedance: 10 KOhm
15 - Parameter Adjustments:
All through graphical user interface software.
16 - CoilA current setting range: ~0 – 3000mA ( with current feedback circuit )
17 - CoilB current setting range: ~0 – 3000mA ( with current feedback circuit )
18 - Coil ‘A’ & ‘B’ Protection: Open and short circuit detect circuit.
19 - Ramp ‘A max setting range: ~0 – 10 seconds up and down
20 - Ramp ‘B max setting range: ~0 – 10 seconds up and down
21 - Dither frequency (Hz ) range: ~0 – 250Hz
22 - Dither amplitude max: ~0 – 5V Pk-Pk
23 - Process ‘P term scale factor range: 0 - 7
24 - Process ‘I’ term scale factor range: 0 - 7
25 - Industry Compliance:
Designed to meet latest CE certification standards
26 - Environmental: Totally encapsulated unit for mechanical protection.
27 - IP rating: IP68 ( Module only - derate for connectors as required )
28 - NEMA rating: 6P ( Module only - derate for connectors as required )
29 - Humidity: 95 – 100% Non condensing
30 - Storage Temp range: -60 to +90 Deg C ( Max )
31 - Operating temp range: -40 to + 85 Deg C ( max )