User Manual
021-MVP-Cxx-(D1) Rev A MVP-C-(D1) User Manual 18
Copyright © High Country Tek, Inc. 2013
MVP-Cxx-(D1) Valve Controller
Application Examples
Single Solenoid Control
The MVP can drive a single solenoid with a signal of 0-5VDC, or 0-10VDC, or 4-20mA.
Mode 1 is used when the enable switch is not used. Mode 3 is used when the enable switch is used.
Set the dither and output settings according to the valve specifications.
FUSE
+V Power Input
9 - 28VDC
+V = Enabled
Brown PWR +
MVPC/D1
Electronic Valve
Controller
White Enable
GRN/YEL
Prop. PWM (Sourcing)
+5VDC @ 2mA
0-5VDC
Red Ref. Out
BLK Analog I/P
Blue GND
VDC I/P
mA I/P
0-10VDC
VDC I/P
4-20mA
Connector GND
Screen
min
Command
Input
Output Current
0
max
min
max