User guide

Hydraulic Generator Controller HGC-2
21
HGC-2 Error code Description (STATUS):
IMPORTANT NOTES:-
ALWAYS Mount HGC-2 controller with I/O connector facing downwards to avoid debris collection.
Recommended tightening torques for securing bolts on the HGC-2 module are as follows:-
For 2 x #6 (4mm) bolts - Dry Torque = 6 Ft-Lbs - Lubricated Torque = 4 Ft-Lbs
Label Inches Millimeters
A 3.0 76.2
B 2.0 50.8
C 0.25 6.4
D 1.0 25.4
E 0.188 4.80
HGC-2 Hardware Description:
Blink Definition
OFF
System is OK and operating normally
2 Open Circuit On Controller Output wires to solenoid disconnected while under power
3 Short Circuit On Controller Output - wires or solenoid have become short circuited
5 Frequency Fault output frequency has been below min. or above max. for greater than fault time
Note:-
The ‘STATUS’ led is a monitor is used to indicate locally the controller operation only
NO external output is provided to mimic the STATUS led