HGC-2 Electrical Specification:
1. Housing Type:- HCT unique ‘encapsulated’ block.
2. Input Supply Voltage: +9 to +28VDC ( Absolute Maximum )
3. Input Supply Current: Valve Current Setting + 50mA Quiescent (Max)
4. **Feedback Voltage:- 100 to 250VRMS ( See note below in yellow box )
5. O/P Current Ranges:- 600mA, 1.2A or 2.5A ( specified at time of order )
6. Solenoid Min Ohms:- 2 minimum resistance
7. Dither Frequency : Software adjustable, ~50Hz to ~1KHz
8. Housing Material:- ABS, black
9. Encapsulation:- Flameproof epoxy resin
10. I/O Connections:- 8 pin Deutsch - DTS06 - Male
11. Mounting:- 2 x No. 6 ( 4mm ) screws .
12. Working Temp.:- -20ºC (-4ºF) to +80ºC (+176ºF) ( operational )
13. Storage Temp.:- -40 (-40ºF) to +85 ºC (+185ºF)
14. Humidity:- 95 to 100% NON condensing
15. NEMA/IP Rating: NEMA 6 / 67 ( module only )
16. Operating System: Windows® XP Professional / Vista
Business, Ultimate & Windows 7 Compatible
17. Unit Settings: All by PC user interface
18. User PC interface P/No:- 023-00228
19. USB Communications: Optical link - Infra-red
20. Interface Cable P/No:- 999-10166
2
1
3 4
1. Main Input /Output connector for HGC-2
2. STATUS led with blink code for local diagnostics
3. Infra-red transmitter lens ( flush with module )
4. Infra-red receiver lens ( flush with module )
HGC-2 Module overview: