Manual
023-00354-Rev1.6 evc/epc User Manual 8
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
LED Diagnostic Codes ( common to both modules )
Module Status LED
GREEN steady -------------------------------------------
Normal operation
RED 1 pulse ----------------------------------------------
Output A short detected
RED 2 pulses ---------------------------------------------
Output B short detected
GREEN 1 pulse ------------------------------------------
Output A open detected
GREEN 2 pulses -----------------------------------------
Output B open detected
RED 3 pulses ---------------------------------------------
Input error detected, reference voltage error
GREEN 3 pulses -----------------------------------------
Power supply error
GREEN 4 pulses -----------------------------------------
Reverse retry fail error
RED 4 pulses ---------------------------------------------
Pot not centered at reset error
ORANGE 1 pulse ----------------------------------------
State error
Communication Status LED
GREEN steady -------------------------------------------
Normal operation
GREEN with ORANGE pulses -----------------------
Serial port (GUI) traffic
ORANGE/ RED pulsing --------------------------------
Receiving SAE J1939 traffic
RED 1 pulse ----------------------------------------------
SAE J1939 set point message timeout
RED 2 pulses ---------------------------------------------
SAE J1939 engine rpm message timeout
RED 3 pulses ---------------------------------------------
Pot not centered at reset error
ORANGE 1 pulse ----------------------------------------
State error