Manual

023-00354-Rev1.6 evc/epc User Manual 34
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Anti-Stall or Horsepower Management With Variable Command
This mode is -stall with Fixed Command
The only difference is that this function allows a variable command input to control the forward speed of the work
function. The max reverse speed of the work function is set by the GUI.
The input can be from an external POT, a joystick or a SAE J1939 message.
At any given forward speed of the work function, the Anti-Stall function reduces the current to prevent the engine
from stalling during a sudden external load increase.