Manual

023-00354-Rev1.6 evc/epc User Manual 22
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Command Input Selection
0-5VDC
0-10VDC
4-20mA
Inverted reverses the response of the command input to output current.
i.e., Minimum command input will give 100% output current and the
Maximum command input gives 0% output current.
For industrial applications that use ±5VDC or ±10VDC, please use a HCT Command Signal Conditioner with the
evc/epc controller.
CSC-0505 accepts ±5VDC and converts to 0-5V.
CSC-1005 accepts ±10VDC and converts to 0-5V.
Loss of Pulse Signal Time (1mS to 65Sec) Sets the time delay
before an error of loss of ulse signal causes to be declared.
Coil A or B default set-point (0-100%) Output A or B will ramp to
this value when the input limits are exceeded or J1939 message times
out, or reference voltage drops to below 4VDC, or the supply voltage
drops to below 9VDC, or the pulse signal is lost.
Command Limit Settings