Manual
023-00354-Rev1.6 evc/epc User Manual 21
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Command & Error Settings
Analog Input Active (On/Off) Enables/Disables
the command analog input.
Analog Center Active (On/Off)
When enabled, the becomes the zero demand point.
Coil A is driven from the center voltage to the max voltage and coil B is driven from the center voltage to the min
voltage
This setting is used in Dual Coil Valve Control only. The is automatically turned
OFF when the Center Active ON
Coil Selection Active (On/Off)
When the input is High, (+5V to Supply Volts) coil B is active and when Low (0V to 2.5V) coil A is active.
This feature allows the full command resolution on coil A and B.
As an example, it is used in the applications where a reciprocating action is triggered by a single high-low input.
Pot Center Error Detection at Initial Turn On
When ON, the module verifies the analog input is in the center deadband range before enabling the output(s)
after the initial power up.
Once the command is centered, the outputs will be enabled.
This safety feature ensures that the system will NOT immediately go to the previous settings after cycling the
power.