Manual
023-00354-Rev1.6 evc/epc User Manual 17
Copyright © High Country Tek, Inc. 2013
evc/epc Controller
With SAE J1939 Interface
Output A or B Coil Settings
Select Coil B Active for a Dual
Coil Valve Control.
Enter minimum, maximum
current and dither frequency
according to the valve
specification.
Enter UP or DOWN ramp times.
memory.
Once the system is running, fine
tune these settings.
Always Active (ON) Output A is always active and cannot be .
Coil B active (ON/OFF) Enables/Disables Output B.
Current feedback (ON/OFF)
ONurrent output is monitored and adjusted proportionally to the demand
within the coil max and min settings.
Current Feedback compensates for supply voltage and coil temperature changes. When disabled,
waveform is adjusted proportionally to the demand between 0% and 100% PWM Duty Cycle.
Inverted (ON/OFF)
ON inversely proportional to the input. This is used with normally closed valves.
When Inverted OFF