Part No:- 021-00351 Rev 1.0 emc-1P & emc-1V e-Fan System Controller User Guide Page 29
e-Fan Cooling System Controllers
with J1939 Interface
Temperature Sensor Information
HCT P/N: 206-00083, Wet fluid temperature sensor.
HCT P/N: 206-00084, Dry fluid temperature sensor.
Main I/O connector & Accessories
Mating connector Parts information: Complete harnesses and connector kits can be supplied by HCT.
Please contact customer service for information.
System Accessories for emc-1P and emc-1V:
Item Description: HCT P/No:
SAE J1939 connector kit for the emc-1P 999 - 10244
RS232 Communications Cable - Weatherpack 999 - 10075
emc-1Main Mating I/O connector Kit 999 - 10155
emc -1Graphical User Interface ( GUI ) replacement Disk 023 – 00264
emc -1Operating Manual 021 – 00351 (see website for latest version)
13.10
24.2 REF
56.1
8.30 DIA
13.00
Sensor Body: Brass
Connector Body: PBT 30%
Glass Filled
Hex Size: 18.9mm / 3/4”
Thread Size: 3/8’ - 18 NPTF
Thread Sealant: GM09985473
Sealing Pressure: 145kPa
Installation Torque: 20Nm
Overall Weight: 40g
Housing Type: Delphi Unique
Typical supply voltage: +5VDC
Dissipation Constant*: 24mW/°C
Thermal Time Constant**: 17.5 to 23.5 seconds
Temperature range: -40 to +150 ºC
( operational )
NEMA/IP Rating: NEMA 6P/68
Contact HCT customer service for more
sensor options and information
Sensor Body: PEI ( polyetherimide )
30% Glass Filled
Connector Body: PBT 30% Glass Filled
Hex Size: 18.9mm / 3/4”
Thread Size: 3/8’ - 18 NPTF
Thread Sealant: GM09985490
Sealing Pressure: 145kPa
Installation Torque: 10.8 - 16.3 Nm
Overall Weight: 13.2g
Housing Type: Delphi Unique
Typical supply voltage: +5VDC
Dissipation Constant*: 18mW/°C
Thermal Time Constant**: 60seconds
Temperature range: -40 to +150 ºC
( operational )
NEMA/IP Rating: NEMA 6P/68