e-Fan Cooling System Controllers with J1939 Interface emc-1P & emc-1V e-Fan Drive - System Controller User Guide High Country Tek, Inc. reserves the right to improve this product at any time and without notice. This manual may contain mistakes and printing errors. The information in this publication is regularly checked and corrections made in the next issue. Please check our website or contact our customer support for latest version.
e-Fan Cooling System Controllers with J1939 Interface High Country Tek, Inc. (HCT) is North America’s foremost independent designer and producer of modular, ruggedized digital and analog electronic controller products for the fluid power industry.
e-Fan Cooling System Controllers with J1939 Interface Table of Contents Welcome .......................................................................................................................4 Introduction ..................................................................................................................4 Cautions .......................................................................................................................4 Warranty Information ..............................
e-Fan Cooling System Controllers with J1939 Interface Welcome Welcome to the High Country Tek Inc. (HCT) e-Fan cooling systems controller user guide, and thank you for selecting this HCT controller to use in your application The following information is designed to allow you to connect, set-up and optimize the emc-1P and emc1V modules. If you have used HCT products before, you will recognize some of the instructions and settings.
e-Fan Cooling System Controllers with J1939 Interface ’emc-1P & emc-1V’ e-Fan System Controller The emc-1P and emc-1V are the latest additions to the High Country Tek (HCT) family of e-Fan control modules. These highly cost effective controllers have all the features and input output functionality that will support a wide range and configuration of e-Fan system applications.
e-Fan Cooling System Controllers with J1939 Interface Product Overview NO software experience needed to apply this controller successfully. Pre-written ‘e-Fan Drive’ software for easy, fast system configuration, development and production. Intuitive Graphical User Interface (GUI) runs on any PC with Windows® XP or newer software (.net compatible). 9 – 32VDC operation with full reverse polarity and SAE J1455 protection. CE approved to latest international test standards.
e-Fan Cooling System Controllers with J1939 Interface Product Application Guidelines ALWAYS do the following Take a few minutes to FULLY read this manual and accompanying data sheets BEFORE starting. Keep High Voltage AC cables separate from Low Voltage DC signal and supply cables. Make sure the unit output voltage is compatible with the equipment being driven! Ensure that you are aware of the adjustments and consequences for the external equipment.
e-Fan Cooling System Controllers with J1939 Interface emc-1P & emc-1v Electrical Specification Overview Board Style ...................................................... High Country Tek unique size and mounting Connector Type (Main) ................................... 12 way male Deutsch IP69K rated Connector SAE J1939..................................... 3 way male Deutsch IP69K rated Communication I/O connector RS232 ............
e-Fan Cooling System Controllers with J1939 Interface emc-1P Module Familiarity Part No:- 021-00351 Rev 1.
e-Fan Cooling System Controllers with J1939 Interface emc-1P Connection Information NOTE: Controller MUST have in‐line fuse fitted by user in the +V Power Input for system protection. SAE J1939 Connections Pin A CAN_Hi (SAE J1939) Pin B CAN_Low (SAE J1939) Pin C No connection Pin 1 ................. Sensor #1 +signal input Pin 2 ................. Fire detect input Pin 3 ................. Fan #1 Diagnostic input Pin 4 ................. Fan #2 Diagnostic input Pin 5 .................
e-Fan Cooling System Controllers with J1939 Interface emc-1V Module Familiarity Part No:- 021-00351 Rev 1.
e-Fan Cooling System Controllers with J1939 Interface emc-1V Connection Information NOTE: Controller MUST have in‐line fuse fitted by user in the +V Power Input for system protection. Pin 1 ....................... Sensor #1 +signal input Pin 2 ....................... Sensor #2 +signal input Pin 3 ....................... SAE J1939 HI input Pin 4 ....................... SAE J1939 Low input Pin 5 ....................... +Volts 9 to 32VDC power supply input Pin 6 .......................
e-Fan Cooling System Controllers with J1939 Interface Error LED Code Descriptions for emc-1P & emc-1V Status Led Error LED Static Flashing Static Static Static Static Static Static Flashing Static off off Static Static Flashing Flashing Flashing Static Flashing Static Description Normal Operation Reverse Cycle Fire Input on Thermistor open/short Fan Diag.
e-Fan Cooling System Controllers with J1939 Interface Module Connection Descriptions Sensor #1 Input (emc-1P & emc-1V) This input is designed to allow non SAE J1939 connected zones to be measured if required. The input accepts a standard NTC thermistor. This input should be referenced to the Signal Ground (0V) on the connector. The GUI is used to select / de-select and set-up the signal from this additional input and how it effects the fan speed control.
e-Fan Cooling System Controllers with J1939 Interface Fan Reverse Switch Input (Momentary contact) This is a momentary signal input and only required that the input be pulled to +5V or Supply Power Supply for approx. 500mS to initiate the reverse sequence settings, this input is debounced in the module software to avoid false triggers. This input may normally be referenced to chassis ground Fire Detect Input: (emc-1P only) Signal input must be pulled to +5V or Supply Power by the fire event.
e-Fan Cooling System Controllers with J1939 Interface Serial Communications Controller monitoring, health checks, diagnostics and set-up can be accessed through the supplied GUI. This program will operate on PC using a Windows® based operating system and is password protected to maintain module parameter integrity by only allowing authorized users to access different levels of the controller settings.
e-Fan Cooling System Controllers with J1939 Interface Loading the emc-1P or emc-1V GUI onto Host PC Both controllers are set-up via a common GUI interface for ease of use. GUI P/N: 023-00264 The PC Graphical User Interface (GUI) is a self-extracting and installing program that will reside on the chosen host PC hard drive. It is recommended that the user allow the defaults to be used for easy future update installation, but the option is given to allow the user to choose where the program should be located.
e-Fan Cooling System Controllers with J1939 Interface Controller adjustments and Monitor After program entries cycle power to ensure changes are accepted by the unit. GUI Menu Options File -> Read file or Save File The user has two simple options available: 1) Read settings from file. This option allows the user to search for and find preciously saved settings files (*.DAT) and to load them into a new controller or to reset a controller to a previous version e.t.c. 2) Save settings to file.
e-Fan Cooling System Controllers with J1939 Interface -> Find Controller Will search the com ports, find the controller, and read settings. Helpful if you have lost communication and or want to do a clean read. Password Protection Enter Password Password entry is started by clicking the ‘Password’ option in the top bar of the GUI screen. This will open a box to enter the passwords. Passwords are ‘cAsE SeNsitivE’ so ensure you have the ‘Caps Lock’ off if required.
e-Fan Cooling System Controllers with J1939 Interface Menu Option ->Help Help View Help This option directs you to emc-1 manual that is part of the installation package. You may add your own docs by adding word.doc or other .pdf files to the same folder. (c:\HCT Products\Fan Drives\emc-1) Print Parameter This will print all settings to your PC default printer. Or print to a text file, tab delimited. The text file may be viewed with Notepad, Word, or Excel.
e-Fan Cooling System Controllers with J1939 Interface GUI software – Main screen (Dashboard) The software has been designed such that there is NO nesting of menus so that it is easy to navigate around the different screens without getting lost or having multiple windows open at any one time. The five main screens are available via ‘Click Tabs’ from the ‘Dashboard’ and are: The ‘Dashboard’ tab provides a quick user overview of the controller operation, system status and condition of the J1939 data Bus.
e-Fan Cooling System Controllers with J1939 Interface Data Logging Start a data log by clicking on this button, data logging will continue until it is turned off by using the same button now labeled “Logging Data” Module Input Voltage Module Internal Temperature Proportional Valve Current Thermistor #1 Temp I/P ( Actual ) Thermistor #2 Temp I/P ( Actual ) J1939 Coolant Temperature ( Actual ) J1939 Inlet Manifold Temperature ( Actual ) J1939 Transmission oil Temperature ( Actual Note: you ma
e-Fan Cooling System Controllers with J1939 Interface General Settings Selection Tab -> General Settings On each tab changes must be ‘Applied’ to take effect. Cancel will restore values. Unit Settings Unit Disabled The controller is shipped in a disabled state and should be enabled by the OEM or user by using the GUI. Once this button is selected, the date from the enabling PC is taken and used as the ‘Born Date’ when warranty starts.
e-Fan Cooling System Controllers with J1939 Interface Output Settings Refer to the requirements set by the fan manufacture for the following 3 adjustments: 1. Minimum PWM% (0-100%) output 2. Maximum PWM% (0-100%) output 3. PWM Freq ( 33-500Hz): This is the ‘dither’ or operating frequency for the PWM% output.
e-Fan Cooling System Controllers with J1939 Interface Input Settings Selection Tab -> SAE J1939 & Discrete Inputs Settings do not take effect until Applied Enable J1939 This option MUST be clicked if the unit is to understand the J19349 Bus information. If this button is NOT clicked, all J1939 features are disabled in the controller. Note: If J1939 messages are enabled, the RPM must be above minimum RPM setting for fans to work in the forward or reverse direction.
e-Fan Cooling System Controllers with J1939 Interface Sensor setup Allows for a switch input or a thermistor input and name for either. Name is useful in data logging and on the Dashboard monitor. As a Thermistor input: Check the Thermistor box, then select profile type from pull down menu, and enter the Start, Maximum, and Alarm temperature values, then Apply Changes. As a Switch input: Check the Switch box, then select Active High or Active Low for the input.
e-Fan Cooling System Controllers with J1939 Interface Error Information Log Selection Tab -> Alarm Condition This page shows the user information that will help to track and where necessary, fix intermittent opens and short circuits on any of the wires used to connect to the sensors, switches or the coils in the system. The program shows where the error has been seen, even if the error has cleared itself.
e-Fan Cooling System Controllers with J1939 Interface Factory Information Selection Tab -> Factory Information This page allows the user to view information concerning the controller serial number, GUI Part number, BIOS and Graphical user Interface (GUI) software versions as well as the ‘Born Date,’ which is taken from the local PC used to activate the module. This information should always be available when requesting support so that HCT personnel know the level of controller with which you are working.
e-Fan Cooling System Controllers with J1939 Interface Temperature Sensor Information HCT P/N: 206-00083, Wet fluid temperature sensor. Housing Type: Delphi Unique Sensor Body: Brass Typical supply voltage: +5VDC Connector Body: PBT 30% Dissipation Constant*: 24mW/°C Thermal Time Constant**: 17.5 to 23.5 seconds Hex Size: 18.
e-Fan Cooling System Controllers with J1939 Interface On Site Testing If the set up procedure does not achieve the desired results, double check the wiring and perform the following tests. Record the test results. Tools Required: A PC running Windows XP, Vista, or Windows7 and the correct emc-1 software are required for initial setup, programming or observation of the controllers operation through the RS232 port (directly or via a USB to serial converter cable).
e-Fan Cooling System Controllers with J1939 Interface If the e-Fan Operation is Erratic: Electrical interference on the control lines can cause erratic behavior if it is strong enough. Observe the control inputs on the PC. If noise greater than a few percent is noticed on an unchanging PULSE IN or COMMAND IN input, or if the digital inputs are toggling, try changing the routing of the control wires to see if the problem changes. Power supply interference or brown outs can also cause erratic behavior.
e-Fan Cooling System Controllers with J1939 Interface emc-1P & emc-1V Dimensional Information Notes: Mount controller as shown or with connector facing down to avoid surface debris collecting. Unit weight is approx. 250 grams RS232 cable removed for clarity RS232 cable is approx 6” long Housing Type ........................... High Country Tek unique ‘encapsulated’ block Housing Material...................... None, solid, flameproof epoxy resin block Housing Color ..........................
e-Fan Cooling System Controllers with J1939 Interface RS232 Communication Cable Part No:- 021-00351 Rev 1.
e-Fan Cooling System Controllers with J1939 Interface Electronic Control Solutions for the Global Fluid Power Industry Mining & Exploration Agriculture Cranes & lifts Refuse & Re-cycling Construction Off-Road vehicles Forestry, Wood & Pulp Reclamation & Salvage Oil Field & Sands Demolition Equipment Cooling Solutions Military Apparatus Specialty Use Remote Control Power Generation Emission Controls Integrated Drivers Valve & Pump Controls HCT Product Sales and Support: