EM Reader Installation and Operation Guide
1.0 Overview
1.1 Introduction
The EM Reader is designed to read and report EM compatible 4000 and 4100 series “read only”
credentials in 26 bit Wiegand format. The reader supports credentials programmed in either F/32 or
F/64 data rates and data coded as Manchester. A bi-color LED and beeper provide visual and audible
confirmation of power and data delivery to the host.
1.2 Unpacking and Identifying Supplied Parts
Unpack the contents and become familiar with the components. The following items will be included with
the EM readers:
1. Installation guide
2. EM Reader
3. Housing label cover
2.0 Installation
2.1 Mechanical Installation
2.1.1 Mounting
EM readers mount to a door frame by drilling two holes sized for 6-32, or M-3 sheet metal or thread-
forming screws 4.92” (125mm) separation. Locate and drill a 0.375” (0.95 cm) hole for the reader cable.
See drawing below for details.
Route the cable through the center hole to the controller. Using the two 6-32 or M-3 screws attach the
reader to the two mounting holes.