1.3 Specifications
• Input Voltage: 12.0 VDC to 24 VDC.
• Input Current/Power
-Typical, quiescent off metal Vin = 12.0 VDC 1.0 A 12 W
Vin = 24.0 VDC 750 mA 18.0 W
-Maximum, quiescent off metal Vin = 12.0 VDC 1.2 A 14.4 W
Vin = 24.0 VDC 920 mA 22.1 W
-Maximum Power 12.0 VDC ≤ Vin ≤ 24.0 VDC 22.1 W
• Recommended Power Supply: Regulated linear power supply
12 VDC at 1.5 A (per reader)
24 VDC at 1.0 A (per reader)
• Read Range with the Indala
FlexCard
TM
Card Up to 28.0” (71.7 cm)
• Operating Temperature Range: -35°C to +65° C (-31°F to +149°F)(See Note 2.)
• Color: Black
• Material: UV resistant, ABS /polycarbonate (UL94V0) plastic.
• Weight (Typical): 3.2 lbs (1.45 kg)
• Dimensions: 11.2” H x 11.2” W x 1.8 “T (28.4 x 28.4 x 4.6 cm)
• Output Formats: Wiegand, ABA track2 Magnetic Stripe. (Contact Factory for
other formats.
• Certification UL-294 indoor and outdoor compliant, CE Mark, and FCC
Class B Digital Device (Part 15) ID Numbers E9U620.
Note 1 Read Range is stated in an undisturbed electrical environment, with card presented
parallel to reader, and reader installed in accordance with Indala instructions. The power
supply, reader and controller must be on the same ground, connected to earth.
Note 2. At temperatures below -20ºC the beeper output may not be audible, except at short
distances.
Note 3. The ASR620++ reader is tuned for mounting on non-ferrous surfaces. If the reader must
be mounted on, or near, a ferrous surface a minimum 3 inch (7.6cm) non-ferrous spacer
must be used.
Note 4. There is no longer a need for the CT-620 power conditioner with the ASR-620++. The
CT-620 was necessary in earlier versions of the ASR-620 to meet European emmissions
standards, but is not needed with the ASR-620++.