User's Manual

____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (714) 598-1600 (800) 237-7769 FAX (714) 598-1690
Web page, E-mail - www.prox.com MIFARE
Wiegand Reader Installation Manual 6074-901 REV 2 2 of 5
Product Specifications
Read Distance
¾ Overall Operating Limits (10VDC - minimum) 1.0-1.5 inches (2.5-3.8 cm)
¾ Non-Metallic Mounting (12VDC - typical) 1.0-1.5 inches (2.5-3.8 cm)
¾ Mounted on Metal (12VDC - typical) 1.0-2.5 inches (2.5-3.8 cm)
Environmental Characteristics
¾ Operating Temperature Range -30
o
C to 65
o
C (-22
o
F to 150
o
F)
¾ Storage Temperature Range -40
o
C to 85
o
C (-40
o
F to 185
o
F)
¾ Operating Humidity Range 5% to 95% non-condensing
¾ Operating Vibration Limit .04 g
2
/Hz 20-2000Hz
¾ Operating Shock Limit 30g, 11mS, Half Sine
¾ Potting Material UL Recognized Filled Polyurethane
¾ Enclosure Material UL Recognized Lexan Polycarbonate
¾ Potted Weight 8.2oz (228grms)
Power Requirements
¾ Power supply Linear type recommended
¾ Operating Voltage Range (+DC) 10.0VDC -14.0VDC
¾ Absolute Maximum (+DC non-operating) 14.0VDC
¾ Maximum Average Current at 12V 60mA
¾ Transient Protection (all terminals) 8,000 volts
¾ Reverse Voltage Protection -15V on all I/O and -35 for power lines
¾ Input Voltage (maximum data-0/1 lines) 15.0VDC
¾ Input Voltage (maximum interface lines) 15.0VDC
Operating Parameters
¾ Excitation Frequency 13.56MHz
¾ Read and Report Speed (26 bit Wiegand Card) 200mS (1K card) + output data
¾ Maximum Cable Distance to Host 500 feet (152 meters)
¾ LED Type Bi-colored Red/Green
¾ LED Operation (host control of red/green)
<
.5V on LED control line
¾ Beeper Operation (host control)
<
.5V on beeper line
¾ Beeper Control (default) Beeper enabled
FCC Compliance Statement:
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
NOTE: THE ABOVE ARE RECOMMENDED INSTALLATION PROCEDURES. ALL LOCAL, STATE
AND NATIONAL ELECTRICAL CODES TAKE PRECEDENCE.