User's Manual
_________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page –
www.proxtrak.com
– ProxTrak Portal Reader Installation Procedure 6042-901-01 Rev 7
27 of 32
Ensure that the amplitude at a frequency between 80 kHz and 200 kHz does not exceed the maximum
noise level amplitudes shown in Figure 5-2 for that frequency. This procedure is repeated for
Figure 5-2. RF Maximum Noise (0 degrees)
-120.0
-100.0
-80.0
-60.0
-40.0
-20.0
0.0
80
95
110
117
120
123
126
129
132
135
138
141
144
147
150
165
180
195
Frequency KHz
dBV
intervals of 22.5
0
between 0
0
and 180
0
. The RF Maximum Noise levels for each of these additional
positions are shown in Figures 5-3 through 5-10.
Portal Threshold
Portal
Uprights
1/2" Spacers
Door Frame
Door
Washer
Upright
Lag bolt
Spacer
Wall
Door frame mount - viewed from the top
Upright/door
frame detail