User's Manual

_________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page –
www.proxtrak.com
– ProxTrak Portal Reader Installation Procedure 6042-901-01 Rev 7
22 of 32
7.4 Indicator actions
Extra
Bit
Actio
n#
Nibbl
e
Action
#
(Hex)
Action Description Comments
0 0000 0 OFF
0 0001 1 ON
0 0010
0100
0110
2
4
6
Short Flash OFF
Medium Flash OFF
Long Flash OFF
Flash Duration set inSet configuration, or
defaults to 1.6Sec on Power-up
0 0011
0101
0111
3
5
7
Short Flash ON
Medium Flash ON
Long Flash ON
Short = 1/16th Duration
Medium = ¼ Duration
Long = Duration
0 1010
1100
1110
A
C
E
Short Flash Cycle OFF/ON
Medium Flash Cycle OFF/ON
Long Flash Cycle OFF/ON
The Cycle action can be used to alternate Red
and Green if used in the same indicator
command.
0 1011
1101
1111
B
D
F
Short Flash Cycle ON/OFF
Medium Flash Cycle ON/OFF
Long Flash Cycle ON/OFF
Cycle action toggles device indefinitely at
Duration rate. Note - ON/OFF or OFF/ON
indicate start/stop state.
0 1000 8 No change for that indicator This action allows commands to be sent to
other indicator(s), without effecting the current
status of the indicator for which it is used.
0 1001 9 Spare
1 0000 0 Spare
1 0001 1 Spare
1 0010
0100
0110
2
4
6
TWO Short Flashes OFF
TWO Medium Flashes OFF
TWO Long Flashes
The extra bit allows special actions; in this
case, two flashes can be activated with one
indicator command.
1 0011
0101
0111
3
5
7
TWO Short Flashes ON
TWO Medium Flashes ON
TWO Long Flashes ON
1 1000 8 No change for that indicator This action allows commands to be sent to
other indicator(s), without effecting the current
status of the indicator for which it is used.
1 1001 9 Spare
1 1010
1100
1110
A
C
E
THREE Short Flashes OFF
THREE Medium Flashes OFF
THREE Long Flashes OFF
The extra bit allows special actions; in this
case, three flashes can be activated with one
indicator command.
1 1011
1101
1111
B
D
F
THREE Short Flashes ON
THREE Medium Flashes ON
THREE Long Flashes ON
The Actions above apply to Red LED, Green LED, Beeper, Relay 1 and Relay 2. “Flash(es) is to be