Web page, E-mail - www.prox.com AMR100 Property Pass Reader Installation Manual 6015-900 REV A 5 of 6
Jumper Block Jumper setting Functional Description
P-5
Ground select
*1-2 Always should be left in this position
P-8
+5v select
*1-2 Always should be left in this position
2-3
P-6 Input communication
protocol select
1-2 RS485 serial input selected
*2-3 RS232 serial input selected
P-9 Output communication
protocol select
1-2 RS485 serial output selected
2-3 RS232 serial output selected
Output path selector P7 #1- P10 #1 Serial output A selected
Input path selector P7 #2- P10 #2 Serial input A selected
485 enable selector P7 #3- P10 #3 485 enable A selected
Output path selector *P11 #1- P10#1 Serial output B selected
Input path selector
*P11 #2- P10
#2
Serial input B selected
485 enable selector
*P11 #3- P10
#3
485 enable B selected
P-17
RS485 Termination
1-2
These should be jumped when the maxitrak is
the last unit on the serial string from the 485
communication card
2-3
(or no jumper)
This setting would apply to all other conditions.
P-18
Beeper enable
*1-2 jumped
Beeper enabled (audible tone will be heard with
each card or asset read)
Beeper disabled
P-19
Tamper switch select
1-2 Tamper output will be Normally Open
2-3 Tamper output will be Normally Closed