Cable Notes:
1) When using
5 conductor cable
, the power supply and Host must have a
common ground
(voltage
reference).
2)
6 conductor cable
is required when controlling the red and green LED. (Alpha 1296 C or equivalent)
3)
7 conductor cable
is required when both green and red LED’s are controlled by the Host and the power
supply and Host "ground" are separate. (Alpha 1297 C or equivalent)
4) A 22 AWG twisted pair, shielded, stranded cable is often required for the
tamper switch
. Follow the
recommendations of the manufacturer of the Host system. If the tamper input is a supervised input the "end
of line" resistors may be mounted in the enclosure. Use extreme care and shield any bare wire from the
printed circuit assembly and its components.
5) The inner diameter of the cable fitting will accommodate a cable with an outer diameter of
.300
inches
(nominally).
6)
Connect cable shield
by connecting drain wire to TB1-2 ground. Leave foil and drain wire disconnected at
host end of cable by cutting them off at the end of the cable jacket.
7) When using the Buffered Direct Connect ProxPro with a
20 conductor
cable, DC+ and Power (Red and
White / Red wires) must have a common connection to the host +DC power supply. The two ground wires
(Black and White / Black) must have a common ground connection to the host +DC power supply.