User's Manual
____________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail -www.hidcorp.com ProxPro Reader Installation Manual 5355A-900 Rev M 10 of 11
ProxPro Reader
™
Specifications
Read Distance - using ProxCard
II
!
Over all Operating Limits, minimum (@12VDC)) 5.0 inches (12.7 cm)
!
Non-Metallic Mounting, typical (@12VDC) 8.0 inches (20.3 cm)
!
Mounted on Metal, typical (@12VDC) 5.5 inches (14 cm)
!
Overall Operating Limits, minimum (@24VDC) 5.5 inches (14 cm)
!
Non-Metallic Mounting, typical (@24VDC) 9.0 inches (23 cm)
!
Mounted on Metal, typical (@24VDC) 6.0 inches (15.2 cm)
Environmental Characteristics
!
Designed for listing under UL 294 “Standard for Access Control System Units”
!
Operating Temperature Range -30
o
C to 65
o
C (-22
o
F to 150
o
F)
!
Storage Temperature Range -40
o
C to 85
o
C (-40
o
F to 185
o
F)
!
Operating Humidity Range 5% to 95% non-condensing
!
Operating Vibration Limit .04 g
2
/Hz 20-2000Hz
!
Operating Shock Limit 30g, 11mS, Half Sine
!
Enclosure Material UL Recognized Lexan Polycarbonate
!
Weight 11.3oz (310gms)
Power Requirements
!
Power supply Linear type recommended
!
Operating Voltage Range (+DC) 10VDC -28.5VDC
!
Maximum Average Current 12V/24V 90mA/155mA
!
Transient Protection (all terminals) UL 294
!
Reverse Voltage Protection YES
!
Input Voltage (maximum data-0/1 lines) 28.5VDC
!
Input Voltage (maximum interface lines) 28.5VDC
Option D – Buffered Direct Connect Keypad
!
Operating Voltage Range (+DC) 10VDC -26VDC
!
Input Voltage (Maximum Data – 0/1 Lines) 14VDC
!
Input Voltage (Maximum Interface Lines) 14VDC
Operating Parameters
!
Excitation Frequency 125KHz
!
Duty Cycle (alternate power level rate) 20% @ 60mS period
!
Read and Report Speed (26 bit Wiegand Card) 175mS
!
Maximum Cable Distance to Host 500 feet (152 meters)
!
LED Type Bi-colored Red/Green
!
LED Operation (host control of red/green)
<
.5V on LED control line
!
Beeper Operation (host control)
<
.5V on beeper line
!
LED Control (default) internal/single
!
Beeper Control (default) Beeper enabled
!
Anti-Pass Back Delay (default) 1 second
!
Wiegand Data Pulse Widths (default) 40uS
!
Wiegand Data Interval (default) 2mS
!
Clock/Data bit time 1.5ms (default)
!
Clock/Data strobe width bit time/3 (33% of bit time), default = 500us
!
Clock/Data clock/strobe is valid 1.5ms (one clock cycle, min) after card present is
!
Asserted data is valid 10us (min) before the
!
negative edge of clock/strobe
card present returns to the high level 50 ms
(max)
after the last clock/strobe.