Radio Frequency Interference
Motors and electronic devices generate RF noise that may interfere with the reception of the signal from a access
card. The effect of RF noise is typically a reduction of read range. The Glass Mount ProxPro is susceptible to RF
interference as are all devices that receive RF signals. Examples are radios, televisions, and cellular phones. The
read range is affected by the amount of interference (noise) in the area. The Glass Mount ProxPro should not be
mounted within ten feet of any monitors (VDTs or CRTs) because the scan frequencies of most monitors include
frequencies that may interfere with the signal received from the access control cards.
Product Specifications
Read Distance
!
Overall Operating Limits (12VDC - minimum) 8.5 inches (21.6 cm)
!
Non-Metallic Mounting (12VDC - typical) 9.5 inches (37.4 cm)
!
Mounted on Metal (12VDC - typical) 6.0 inches (15.2 cm)
!
Overall Operating Limits (24VDC - minimum) 9.0 inches (6.3 cm)
!
Non-Metallic Mounting (24VDC - typical) 10.5 inches (22.9 cm)
!
Mounted on Metal (24VDC - typical) 7.0 inches (17.8 cm)
Environmental Characteristics
!
Designed for listing under UL 294 ā€œStandard for Access Control System Unitsā€
!
Operating Temperature Range -30
o
C to 65
o
C (-22
o
F to 150
o
F)
!
Storage Temperature Range -40
o
C to 85
o
C (-40
o
F to 185
o
F)
!
Operating Humidity Range 5% to 95% non-condensing
!
Operating Vibration Limit .04 g2/Hz 20-2000Hz
!
Operating Shock Limit 30g, 11mS, Half Sine
!
Enclosure Material UL Recognized Polycarbonate
!
Weight 13oz (364gms)
Power Requirements
!
Power supply Linear type recommended
!
Operating Voltage Range 10VDC -28.5VDC
!
Maximum Average Current 5V/12V 150mA
!
Transient Protection (all terminals) UL294
!
Reverse Voltage Protection YES
!
Input Voltage (maximum data-0/1 lines) 28.5VDC
!
Input Voltage (maximum interface lines) 28.5VDC
Operating Parameters
!
Excitation Frequency 125KHz
!
Duty Cycle (alternate power level rate) 20% @ 60mS period
!
Read and Report Speed (26 bit Wiegand Card) 175mS
!
Maximum Cable Distance to Host 500 feet (152 meters)
!
LED Type Bi-colored Red/Green
!
LED Operation (host control of red/green) <.5V on LED control line
!
Beeper Operation (host control) <.5V on beeper line
!
LED Control (default) internal/single
!
Beeper Control (default) Beeper enabled
!
Anti-Pass Back Delay (default) 1 second
!
Wiegand Data Pulse Widths (default) 40uS
!
Wiegand Data Interval (default) 2mS
Note: The above are recommended installation procedures. All local, state and national electrical
codes have precedence