Wall Mount Installationarts List
1) ProxPro Plus Reader, Rear Cable Exit qty 1 ea (included)
2) This Installation Manual qty 1 ea (included)
3) Screw, self tapping, 6-32 x 1.00, pan head qty 2 ea (included)
4) Screw, machine, 8-32 x .875, flat head 82
°
, black qty 4 ea (included)
5) Nut, clinch, black qty 4 ea (included)
6) 5 conductor Alpha 1295 C or equivalent. See cable notes. User supplied
As required, up to 500’
7) Power Supply Requirements User supplied
Linear, 10-28.5VDC, 120mA
When using a gang box:
"
Drill a
∅
.188 hole in the 2 locations shown in figure 5.
"
Insert the 6-32 clinch nuts 4 places in back.
"
Mount reader to gang box using 6-32 self tapping screws.
"
Return cover using 8-32 machine screws. Ensure that the LED lens on the cover is lined up with the LED.
"
Apply “HID” label such that it is right side up.
When not using a gang box:
"
Return cover to base using screws provided with reader. Ensure that the LED lens on the cover is lined up
with the LED.
"
Mount reader to wall using the 4 corner holes in the case.
"
Apply the “HID” label such that it is right side up.