User's Manual
HID CORPORATION
3
PRE-PROGRAMMING THE UNIT
BEFORE INSTALLATION
Dealers and installers are advised to pre-program the unit at
their offices before installing it at the site. Simply connect it
to a 12VDC source, follow configuration and card enrollment
instructions at the end of this guide, and disconnect the unit.
Programming will be retained in memory. You will spend
less time at the site, and by being familiar with programming,
will be able to train the end user more effectively.
SPECIFICATIONS
TABLE 1 - SPECIFICATIONS
CATEGORY REQUIREMENTS
Environmental
Operating
Temperature
–31F to +150F
(-35C to +66C) @ 30 VDC
Operating Humidity 5% to 95% relative humidity,
non-condensing
Electrical
Power
Supply/Current
Requirements
10 - 15V DC, linear, filtered
and regulated power supply
recommended 150 mA for the EntryProx
unit only.
Additional capacity required for locking
device or peripherals.
Mechanical
Height 5.25 in (13.3 cm)
Width 2.75 in (7 cm)
Depth 1.625 in (4.1 cm)
Relay Outputs
Main Relay, Aux Relay Form C (switches up to 1A inductive
load, 2A resistive @ 30VDC)
Sounder 4000 Hz, defeatable
LEDs Bi-Color (red/green)
Amber
Infrared