User's Manual
HID CORPORATION
37
WIEGAND MODE
If you program the EntryProx unit to operate in Wiegand
mode with a separate access control panel, the following
features are not accessible:
• The EntryProx unit does not control door lock or
unlocking
operations.
• The EntryProx unit is not able to store codes in memory.
• The main and auxiliary relay functions are turned off.
• The door monitor and Request to Exit inputs are disabled.
For more information on programming the EntryProx unit
for Wiegand operation, please contact your local distributor.
PIN CODE OUTPUT IN WIEGAND MODE
The system transmits keypad PINs while operating in
Wiegand mode by processing any digit sequence terminated
with the [*] key as 26-bit Wiegand data. The current facility
code (set using Code 32 - 2) will be used. Entering any PIN
over 65535 will cause an error condition and no data will be
sent.
Because keypad data is sent in a card data format, it may not
be possible for some panels to perform CARD AND CODE
operation (requiring both) to gain access. If your panel cannot
accept and interpret 26-bit format as PIN data, be sure to
configure the user at the PC host software by entering the
code into the CARD data field for that user, not the keypad
PIN number field.