WIRING THE REQUEST TO EXIT INPUT
When the EntryProx Request to Exit (REX) input receives a
momentary switch closure, it engages the main relay for the
programmed access time. It can be connected to a wall-
mounted exit button, to a push button under a reception
desk, or to the relay output of a passive infrared motion
detector mounted above the door on the secure side. The
Request to Exit input activates the alarm shunt to prevent
false alarms when personnel use the controlled door to exit
the secured area. The Transaction Log records all Request to
Exit usages for monitoring purposes.
To wire the EntryProx Request to Exit input, refer to Figures
16 and 17.
Locate connector P2 on the main circuit board and remove
the 2-pin jumper installed on pins 5 and 6.
Refer to Figure 17 to make the wiring connections to the
cable assembly if you are NOT using a door contact
.
Note: If you do not use a door contact, you need to twist the
white and orange wires together or the REX input will not
function.
Note: The door contact
must
be closed for the Request to
Exit feature to work properly