User's Manual

Static Collection and Data Transmission
Preface
V60 receiver can be used in double-frequency static
measurement. The setting method is double clicking Fn key,
and then the voice broadcast will enter into work mode.
Continue clicking Fn key and the work mode of voice
broadcast is static mode when the satellite light and state light
are on. Click power key to confirm. After successful setting,
the red state light will flash one by several seconds (according
to the sampling interval), one epoch will be collected by one
flash. The static data can be stored in host or SD card. If the
static data document shall be downloaded to computer, it shall
use static post-processing software to process.
Static Measurement
1. Setup the instrument in measurement point; align and level
the instrument.
2. Measure height of the instrument for three times; the
difference between two times shall not be more than 3mm; the
average is regarded as the final height of instrument. Height of
instrument refers to the distance between center of
measurement point and measurement marker line of
instrument.
3. Receiver parameters:
Receiver radius 91mm
The height from receiver bottom to phase center of
antenna is 94.2mm
40