User's Manual

V60 GNSS RTK System Operation Instruction
socket/five-core socket external power supply. Where:
The receiver will automatically start after energizing eight-core
socket external power supply
The receiver will start through pressing the power button on
control panel after energizing five-core socket external power
supply.
The external voltage range of GSM operation mode is DC 6-28V.
The current shall be more than 1,000 mA. Upon external power
supply, the host will automatically detect the voltage of lithium
battery and external power supply, and supply power choosing
higher voltage. As for external power supply, it shall use the
special power specified by Hi-Target.
Note: 1. The service life of lithium battery will
decrease along with the decrease in
temperature and increase in
charging-discharging times. A new 5000
mAh lithium battery can be used for 12
hours upon collection of static data, 9 hours
upon GPRS rover.
2. After using up, it shall charge the battery
within 24 hours, or the battery performance
will be damaged.
3. When the battery is not used for a long time,
19