User's Manual

Static and Data Transmission
Management Software Operation For Static
Survey
The main function of static file management software of IRTK
receiver:
Delete original data
Delete and format the whole
Read parameters, Set parameters
Operating steps:
1. Connect Y type data cable to 8-pin port of iRTK receiver
and the series port of PC
2. Choose the right PC port and click “connect port
3. Refresh list, the observation data files will be in the list
4. File name: 8 digit character: the first chart is replaced by
underline; the second, third, and forth are the last two numbers
of S/N number of the receiver from which the data is collected;
the fifth, sixth, and seventh is the year-accumulated-date; the
last chard is the collecting period of the day
5. Set up time: GNSS time.