Static and Data Transmission
Fig 5-1
3. Record point name, instrument S/N, instrument height,
observing initiated time
4. Turn on the instrument and set the main frame as static
surveying mode. The satellite LED flashing means the
instrument is searching the satellites. The satellites are fixed
once the satellite LED turns into constant on. Status LED
flashes due to your collection interval set. The default
collection interval is 5 seconds, which means an epoch will be
collected every 5 second. In static mode, the receiving LED is
off.
5. Turn off the instrument after the static survey is done and
record the turn-off time.
6. Download and post-process data
Note: Don’t move the tribrach nor change the collecting set while the
instrument is collecting data.
Download Data with U Disc Download
iRTK saves the files with U disc download in file management,
i.e. you can download the files by drag-drop. The static survey
data only can be downloaded but not to re-write the data.
The data of iRTK receiver ca n be downloaded in U disc
download, you can use Y type data cable, connect one side to
USB port of PC and the other side to the 8-core jack of main
frame. After connected, RTK iRTK new disk symbol shows up
in the PC, like U disc download, you can copy the according