User's Manual

69
Instrument center
Measured point 2P2
Measured point 1P1
Target point
TGT
Station
Target height
Target height
1) In the offset menu, press [3] or press [ENT] after moving
the cursor to “Offset/2D” to enter the interface of
“Offset/2D->Pt.1” ,as shown in picture (1);
[MSR]
HR:
VZ:
SD:
*Take 1st
1
Offset /2D->Pt.1
MSR1
MSR2
HR:
VZ:
SD:
*Take 2st
Offset /2D->Pt.2
MSR1
MSR2
2
P1-P2:
P2-TGT:
3
Offset /2D->Input
ENT
[MSR] [ESC]
ESC
35°3417
69°4211
m
36°3417
69°4311
m
3.893
m
m
2) Aim at the measured point 1 and press [MSR1] or
[MSR2] to start measuring. When finish the
measuring, enter the interface as shown in picture
(2);
3) Aim at the measured point 2 and press [MSR1] or
[MSR2] to start measuring. When finish the