User's Manual
41
of remote elevation measurement is below:
[ENT]
【ENT】
(2)
(1)
(3)
[ESC]
【ESC】
MSR1 MSR2
KNOWN
RBM->Input
0.000
12345
Code:
m
7
Pt.:
T.H:
RBM->Meas.
HD:
m
m
VD:
HR:
*[ENT] save after meas.
91º42′34"
0.145
0.560
RBM->Result
Z:
m
m
m
E:
N:
STN:
I.H:
0.300
m
-23564.203
-29546.256
-0.300
2
1
1
1) Press the key [5] or select “5.Remote BM” and press [ENT]
to enter the interface of “RBM->Input” interface,as shown
(1) below;
2) Retrieve the point (see the chapter 4.8), then the display of
“Pt .” will be refreshed, at the same time, the cursor moves
to the input box of “I.H” (instrument height);
3) Input target height in the “I.T” input box and press the key
[ENT] to enter to the interface of “RBM.->Meas.”, as
shown above;
4) Press [MSR1] or [MSR2] to start measurement. after a
successful measurement, the values of “HD” and “VD” are
displayed;
5) Press [ENT] to enter the interface of “RBM->Result” ,(as
shown (3) above) ;
6) Re-input the instrument height in the “I.H” interface;
7) Press [ENT] with a prompt “STN-Up-to -date” and come
back to the stationing menu.