User's Manual
34
“AVG”: The cumulative average values of horizontal
angle.
“Angle”: The real-time angle value between the backsight
point and the foresight point after every repeated measurement.
“Read”: The number of completing angle repetition
“HD”: The horizontal distance value of the foresight point
measured.
2) According to the prompt “Aim BS.”, aim at backsight
point, and then press [ANG];
3) According to the prompt “Aim FS.”, turn the
instrument (the angle is changed in real time),and press
[ANG].After these operations, a angle measurement is
completed , and the values of “SUM”,“ AVG”, “Read”
will refreshed;
4) Repeat the operations of step “1)” and “2)”,but a
maximum of ten angle repetitions is allowed. If you
press [ESC],the operation of this angle repetition will
be canceled and return to the previous operation;
5) You can measure the distance of the foresight point
with the keys [MSR1] or [MSR2] after aim at the
foresight point and press [ANG]. If press [ENT] again,
you can record the measured data;
6) Press [ESC], and the interface will come back to angle
menu.