User's Manual

33
Hold->Set
HOLD
HR:
*Keep until release
1
Hold->Set
REL.
HR:
*Keep until release
[HOLD]
2
20°2739
20°2739
2) Enter to the “Hold -> Set”(1),then turn the instrument
and the horizontal will be changed in real time. Then,
press [HOLD], the current value will be held with
unchanged and enter to the interface (2);
3) Turn the instrument at a right direction, then press
[REL.], the interface will come back to the basic
measurement with the current horizontal angle set as
the held angle;
4) Press [ESC] and the interface return to the angle menu.
5.4 HA Repetition
This function is to obtain the angle between backsight point
and foresight point with repeated measurement, and can get the
coordinates of the foresight at the same time.
1) In the angle menu interface, press[4] or press [ENT]
after moving the cursor to “4.Angle repetition”to enter
the angle repetition interface ,which as follows:
MSR1
ANG
Avg:
Sum:
Angle:
MSR2
Read:
HD:
*Aim FS.
ESC
0000
0000
0000
Cnt. 0
m
[Note*]:
“SUM”: The cumulative measured values of the horizontal
angle.