User's Manual
16
unit to make sure it is secured to the tripod.
3) Using the circular level to level the instrument coarsely
① Twist and adjust the two leveling screw A and B on the
bottom of the instrument until the bubbles of the circular level
moves to the line perpendicular to the center line the screw A
and B;
② Twist and adjust leveling screw C to move the bubble to
the center of the circular level.
center
buble
Screw C
Screw B
Screw A
4) Using the plate level to level the instrument precisely
① Loosen the horizontal locking screw and turn the
instrument around until the plate level is perpendicular to a line
shaped with screws A and B. Adjust the screws A and B to make
the bubble in the center of the level;
Screw C
Screw B
Screw A
② Turn the instrument approximately 90° and adjust screw
C until the bubble in the center of the level;