Chapter 8 System Parameters and Comm ands
Hi-G-Tek Ltd. Micro electronics & Asset Tracking Technology - 223 -
Reader Reset Timeout
Property Name
(not supported).
Access
Read & Write.
Data Type Integer
Constant in
H G TRe a de rPa rame te rCo de En um
(not supported) (10h).
Description
Determines the maximal interval in
seconds that the DataReader will
wait for a command from the
controlling computer before it will
reset itself.
Remarks
If this parameter is not 0, then the DataReader will reset itself if it does not
receive a command from the controlling computer in the duration specified
by this parameter's value. This is like a "watchdog" for the RS-232/485
communication.
You should set this value to the biggest gap you expect between 2
commands that are addressed to that DataReader. If you set this parameter
to 0, and there is a problem with the RS-232/485 communications you will
have to reset the DataReader manually.
Chain NOP Interval
Prope rty Name Ch ain No pInte rval
Access
Read & Write.
Data Type
Long. Max value: 65535.
Constant in
H G TRe a de rPa rame te rCo de En um
(not supported) (11h).