User Manual
Table Of Contents

Chapter 8 System Parameters and Comm ands
Hi-G-Tek Ltd. Micro electronics & Asset Tracking Technology - 209 -
process begins.
If the HF flag in the Application Flags parameter is 1 and the Sealing
Wire is closed, the command fails.
In Deep Sleep mode, built-in tests and Sealing Wire resistance checking are
not performed. The DataSeal wakes up in Tp intervals to check for a Hard
Wakeup command.
Hard Wakeup
Me thod Se als.DeepSleep
Description
Wakes up DataSeals that are in Deep Sleep mode.
Remarks
When a DataSeal receives this command it performs the following actions:
1. The Deep Sleep flag is cleared.
2. The wakeup interval of the DataSeal returns to be Tw (instead of Tp ).
However, built-in tests and Sealing Wire resistance checking are not
performed unt il t he successful complet ion of t he next Set, Suspen de d
Se t, or Soft Set command.
Start Alert Burst Mode, Stop Alert Bust Mode
Method Seals.SetAsyncAlertBurstMode
Description
Starts or stops the specified DataSeals from being
in Burst Mode.
Remarks
The method has a boolean argument called BustMode that determines
whether to perform Start Alert Burst Mode co mm an d o r a Stop Alert
Bu rst Mode co mm an d.
When a DataSeal receives this command it sets (Start) or clears (Stop) the