User Manual

Chapter 8 System Parameters and Comm ands
- 208 - Hi-G-Tek Ltd. Micro electro nic s & A sset Tra cking Techno logy
Remarks
When a DataSeal receives this command it performs the following actions:
1. Clearing the following Status flags: Ta m p e re d , Low Batte ry
Warning, Opened, Suspen de d Se t an d Sealin g Wi re Ch ange d.
2. Write a new Soft Se t Event record.
3. The Last Set Reade r ID parameter is updat ed.
The Soft Set command fails in the following situations:
The DataSeal is in Deep Sleep mode.
Li fe Coun te r is 0.
The DataSeal's internal database is corrupted.
The Low Battery Error flag is on.
The Sealing Wire is open.
Re se t Dat a
Me th od Se als .ResetDataBl ock
Description
Initializes all the User Data memory to 0's.
Deep Sleep
Me thod Se als.DeepSleep
Description
Puts the specified DataSeals in Deep Sleep mode.
Remarks
When a DataSeal receives this command it performs the following actions:
1. The Deep Sleep flag in the DataSeal's Status is turned on.
2. A Dee p Slee p Event is written.
3. If the Alert Burst Mode flag is on, an Ale rt Bu rs t message sending