Start Forced Burst
Method Seal.StartForcedBurst
Description
Instructs the DataSeal to transmit a special Burst
message according to the specified arguments.
Arguments:
Name Type Description
M a sk HG TVerify MaskEnum
enum eration
The set of parameters that you
want the DataSeal to transmit in
the Forced Burst m ess ag es. U s e
t h e 'O r ' op er ato r to com bi n e m o r e
than one constant from the
HGTVerifyMaskEnum
en um erat ion.
Phase Long The interval in milliseconds since
the DataSeal received the
command and until it should start
sendin g the Forced Burst
messages.
Period Long The mean interval, in miliseconds,
between retries (retransmits) of
the Forced Burst messages.
RandomDiff Long Th e range, in mili seco nds, of th e
random variance from the mean
interval between retries of the
Forced Burst messages.
Retries Byte T he m axim um n umb er o f ret ri es
that the DataSeal will send.
S pecify 0 fo r unlim it ed n umber o f
retries. Specify 255 to stop the
DataSeal from sending further
Forced Burst messages.
UserCode Byte A general purpose value that will
be sent in th e Fo rced B urs t