User Manual

Chapter 8 System Parameters and Comm ands
Hi-G-Tek Ltd. Micro electronics & Asset Tracking Technology - 153 -
Maxim al Alert and Close Burst Retries
Seal O bject Property MaxAlertBurstRetries
Access
Read & Write.
Description
Determines the number of times that
the DataSeal will transmit an Ale rt
Burst message or a Close Burst
message if it doesn't receive an
acknowledge.
Constant in
HGTSe alParameterC ode Enum
H G TMa x Ale rt Bu rs tRe t ries (7 6h).
Verify Mask in
HGTVerifyMaskEnum
(not supported).
Data Type Byte
Default Value
10
Remarks
See also the Ale rt Bu rs t Pe ri od parameter.
Maxim al Deep Sleep Burst Retries
Seal O bject Property MaxDeepSleepBurstRetries
Access
Read & Write.
Description
Determines the number of times that
the DataSeal will transmit a Dee p
Sleep Burst message if it doesn't
receive an acknowledge.
Constant in
HGTSe alParameterC ode Enum
HGTMaxDeepSleepBurstRetries
(78h)