The largest block size that can be written in one session is 67 bytes.
If the parameters of the command are invalid, or the DataSeal can't perform
t he command due t o any other reason, it responds wit h message t ype E8
(hex).
This command is an Addressed command, and therefore the Seal ID of the
addressed Dat aSeal has t o be ent ered in the Seal s /Tags ID field before
executing the command.
The Command Data is composed of the following arguments:
Argument Value in
example
Description
P/#PK 11h Packet number out of total number of
packets. At this stage this argument is
not in use and must be 11h.
Base Address 0 The address in the DataSeal's User
Data memory to where you want to
write the data.
Data (All the
rest)
The data to write to the DataSeal's User
Data memory. This field can have any
length up to 67.