Hi-G-DataReader Operation
Three LED light indicators are located
on the left-hand side of the electronics
compartment.
Power: The DataReader is activated by connecting it to a power
supply. At power ON and self-test the power indicator alternates
between the GREEN and RED indicators for several seconds.
If the check result is OK, the indicator remains GREEN. If a
problem was detected, the indicator remains RED.
When performing firmware download:
- MCU download, the indicator alternates between GREEN
and RED
- AVR- the indicator remains off
Channel 2 SD/RD:
When the indicator is red, the unit is in SD (sending data) mode.
When the indicator is green, the unit is in RD (receiving data) mode.
When the indicator is off, it is in stand-by mode.
Channel 1 SD/RD:
This channel is optional. The indicators operate in an identical
manner to those for channel 2:
When the indicator is red, the unit is in SD (sending data) mode.
When the indicator is green, the unit is in RD (receiving data) mode.
DataReader Operation Instructions
4
Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
48