Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
155
6
RS 485/232 Communication Protocol
Data**
TF TID Message Type Data Results
2 4 1 # of bytes
If no seal detected:
Data*1
Seal record
#B=0
1
6.5.5.6. Reset Reader.
6.5.5.6.1. Command Transmission
This command performs a general reset to all readers at one time.
In this command, the LSC does not prompt.
LSC > Reader
STX #B R# CMND(0014h) CRC ETX
1 2 2 2 2 1 # of bytes
Where:
#B
DATA**
is the number of bytes for a seal record (including
the #B fiels).
is the data received after executing the RF command
led by TF, TID and Message Type