User's Manual

Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
116
RS 485/232 Communication Protocol
6
6.1. RS- 485/232 Communication Protocol:
General Description
Communication between the Local Site Controller LSC and the
STAR READER is based on the master/slave approach. The LSC
is the MASTER unit, the READERS are the SLAVE units.
The LSC and the READERS communicate via a RS-485 multi
drop or RS-232 connection. Each READER has its own address,
enabling the LSC to approach each reader individually.
6.2. Physical Layer
6.2.1. Down-link
Down-link is the link from the LSC to the READERS. The link is
RS-485 or RS-232 half duplex. Data rate can be one of the
following: 2400, 4800, 9600, 19200, 38400 BPS. The default rate
is set at 9600 BPS.
6.2.2. Up-link
Up-link is the link from the READERS to the LSC. The link is
RS-485 or RS-232 half duplex. Data rate can be one of the
following: 2400, 4800, 9600, 19200, 38400 BPS. The default rate
is set at 9600 BPS.
6.3. Protocol Flow.
Communication is initiated by a command sent by the LSC to the
READER. The READER executes the command and responds
accordingly. In a long command session, the session is concluded
when the LSC acknowledges the READER within T = 50 msec.
ACK
If the READERS are in sleep mode, the LSC must ensure they are
awakened prior to the initialization of the session. In this case, the
LSC should wait T = 50 msec before sending the main command.
w