User's Manual

Hi-G-Tek Ltd. Microelectronics & Asset Tracking Technology
125
6
RS 485/232 Communication Protocol
Ch1err
Ch2err
Ch3err
Ch4err
If 0, channel is OK
If 1, channel is defective, details are in byte C. If
byte C flags are OK, there is a communication
failure with this channel.I
If 0, channe2 is OK.
If 1, channe2 is defective, details are in byte C.
If byte C flags are OK, there is a communication
failure with this channel.
If 0, channe3 is OK.
If 1, channe3 is defective, details are in byte D. If
byte D flags are OK, there is a communication
failure with this channel.
If 0, channe4 is OK.
If 1, channe4 is defective, details are in byte D.
If byte D flags are OK, there is a communication
failure with this channel.
Bytes C&D:
VCCERR
PMC
EMC
EME
If 0, power is OK.
If 1, power is not faulty
If 0, program memory in the module is OK.
If 1, program memory is corrupted.
2
If 0, E ROM is OK.
2
If 1, E ROM was corrupted and then restored.
2
If 0, E ROM is OK.
2
If 1, E ROM was corrupted.